b) WFE-VB type shaves the membrane evaporimeter
|
WFE-VB type shaves the membrane evaporimeter
, it shaves form of the diaphragm and is
similar to shaving the board agitator ,
uses a rigidity blade rotor equipment (Fig.
2). It blow diaphragm length and heat surface
with high , according to blow diaphragm
width and size of the evaporimeter adjust
to and heat interval 1mm of cliff side,
so does not produce wearing and tearing
in heating the surface. It is easy to wash
that this seals type structure and very
smooth and superficial rotor , so, the supplies
are suitable and in extensive range, very
suitable for the food trade, GMP suitable
for the medical trade too is required. It
can deal with viscidity to probably product
of 50,000mpas WFE-VB WFE-VB type blow rigidity
blade , membrane of evaporimeter can make
spiral form too , deal with viscidity can
reach product of 70,000mpas at this moment
。
Shave the board material and adopt the
material the same as barrel of the evaporimeter
。 |
c) WFE-VC type shaves the membrane evaporimeter
:
Also call hinge blow membrane evaporimeter ,
it have one centre go back pivot , transport
hinge blow the diaphragm (Fig. 3), they stick
and become certain angle to slip in heating
the cliff side closely by the centrifugal force,
shave the supplies into the necessary liquid
film, prevent heating the surface and forming
the dirt , forms burntly . Offer effective impaction
strength the design , rotor of types about liquid
film (the high to evaporate than and concentrate
not low) 。
It is it heat surface apt form dirt , have
solid particle or prone to crystallization in
the course of evaporating and is it concentrate
supplies that do to demand to suited to, deal
with viscidity to 35,000mpas 。
The type of this kind of rotor is used extensivly,
by changing and shaving frequency of the board
and quality, regulate the centrifugal force
。
Shave the board material and usually adopt
the metal material the same as barrel of the
evaporimeter , can adopt PTFE material 。
d) WFE-Vd type shaves the membrane evaporimeter
|
Also call flexibility blow membrane
evaporimeter , with cannelure to slip piece
fix in " L " in the trough, depend
on the centrifugal force and double load
function of elastic strength and transform
the supplies into the liquid film in heating
the surface, pass and adjust in adjustable
liquid film the time of staying of angle
of cannelure too. This kind blow diaphragm
pattern utilize elastic and load that strength
produce , particularly suitable for the
high viscidity and get the supplies that
are inclined to together, it has very good
cliff side to clean function by oneself
。
It blows the diaphragm material for PTFE
or formates such similar materials as the
graphite ,etc. 。 |
● The WFE-KV type vertical cone shaves the membrane
evaporimeter
WFE-KV type blows their of the membrane evaporimeter
and shaves form of the membrane device and shaves
one for rigidity , the structure is a round
tapered barrel for the cylinder type barrel,
underpart (low evaporating area ) for the top
of the evaporimeter (high evaporating area );
Is it is it transfer cotyledon slice to to regulate
to move by axial , can adjust rotor blow the
diaphragm and heat the Taxi interval in low
person who evaporate. It heat assurance surface
the even to get moist,even not at concentrate
low emission (the higher to evaporate than)
when can get, meanwhile , can change thickness
of liquid film (make a reduction of thin ) and
the time of staying (extend), make the evaporation
course here improved 。
It is very suitable for demanding the few
products of implicit low boiling thing composition
of remaining amount, viscidity is probably in
50,000mpas 。
● The WFE-KH type horizontal cone shaves the
membrane evaporimeter
The horizontal cone shaves the membrane evaporimeter
and is very similar to shaving the membrane
evaporimeter round and tapered vertically ,
as for structure being similar, but the following
performance are different :
Light group one (low boiling thing ) and the
liquid film (high boiling thing ) flow suitably
, suitable for flowing into the overheated supplies
directly, steam and enter the evaporimeter by
flashing ;
It has longer the time of staying, and flow
in the direction and gravity and become 90 degrees,
still can be used as the reactor ;
Low space requirement, WFE-KH evaporimeter
can be placed on if the existing building is
highly restricted, it can not place the place
of the vertical evaporimeter ;
This type evaporimeter is suitable for viscidity
probably in 70000mpas ;
|