HEC PRODUCTS
 
≡ Membrane evaporimeter
>>>>Present page :Membrane evaporimeter
HEC PRODUCTS:

All theories :
  Will it be the fifties the 20th century, " Luwa ", office of country, and " Samesre uther " Company to blow membrane evaporimeter is it make to develop already right away, have developed and shaved membrane evaporimeters so far and has already been generally approved and accepted by everybody. HEC Company develops the company as the speciality of the evaporimeter today, in distillation, concentrate , take off angry decolouring , taking off bad smell dry reacting field solve the problem that deal with the course and special demand in different crafts; It offer the getting more extensive, blow different kinds of one by membrane evaporimeter application,such as :
  1.Offer suitable various kinds of rotor types used differently in extensive range of one ;
  2.Vertical or horizontal structure ;
  3.Cylinder or designing taperedly ;
  4.Obey flowing or adverse current operation principle ;

Characteristic:
  Shaving the membrane evaporimeter has the following technological characteristics and other evaporimeters different mainly :
● It is great to operate the elasticity :Some performance alone because of shaving the membrane device , make it is it deal with apt to form dirt , crystallization , bubble and demand evaporate , high viscidity and raise the supplies that viscidity increase with the density sharply steadily to suitable for, it can be dealt with to evaporate course steadily too 。
● Operate in succession :Continuous charge-in , producing material in succession , regulate the amount of material entered and control out the density of material ;
● Deal with temperature sensing :Because time when staying in the short one in the whole device and low evaporation temperature ;
● Evaporate performance high :Because of shaving the characteristic of the membrane device , heat the hot flux of surface with height of surface ;
● It is minimum to lose :In case the products change losses minimum, because the supplies have not been held up in the evaporimeter ;
● The vacuum pressing and lowering small :Supplies vaporize gas from heat surface send the condenser put outside to , need certain difference of keeping. In the general evaporimeter, this kind of difference of pressing is required (?÷p)It is usually higher, it is even high sometimes difficultly to accept. Blow membrane evaporimeter have bigger gas pass through space , evaporimeter pressure can regard as pressure in condenser nearly equal to, so keep difference can very much little namely the vacuity can up to 1mmmHg 。

Performance of the device :
Parameter Performance
Amount of material entered (Kg/h) 20-10000
Evaporation capacity (Kg/h) 40000
Heating temperature (℃) 330
Operate the pressure (the material side)  (Torr) -1-30*1
Make the viscidity of the products in operation temperature  (mpas) 到70000
The time of staying   (min) <1*2
Evaporation than (concentrate /charge-in) 到1:50*3

*1、The temperature of heating with electroinduction evaporimeter can be up to 600 degrees Centigrade ,
*2、Perhaps the time table is relatively long in the horizontal evaporimeter ,
*3、According to the type of the evaporimeter 。
WuXi HeXiang Biochemistry Equipment Co.,Ltd. Http://www.heczb-cn.com Http://www.hexzb-cn.com E-mail:sales@heczb-cn.com
Tel:0510-83796122 83217202 Fax:0510-83799122